Tension Controller TC-2010 is developed for the multi-motor proportional speed control and interlock in the production, it is suitable for the tension control of material in the feeding process, is an economic type Tension Controller. |
|
 |
• |
It is suitable for the tension control of material in the feeding process, its functions are simple and is easy to operation. |
• |
Receiving tension detector’s signal (LMS series, PSD series Tension Detector) and it is the signal source of tension of material in process. |
• |
Function of proportional speed and interlock could keep material’s tension be stable in the procedure of production. |
• |
Ability of multi-level P.I.D operation could quickly stabilize the tension change in the production of material. |
• |
Variety of control to drives: Torque Controller · Vector Inverter · DC Motor Drive · Servo Motor Drive. |
• |
Function of RS-485 communication could communicate to PLC, HMI and IPC for control. |
|
 |
 |
 |
Tension controller TC-2010 |
 |
 |
System |
 |
Applicable mode |
Central guiding control |
Applicable load |
5 ~ 2,000Kg |
Rated output |
DC 0 ~ ± 10V |
Power |
AC 1∮, 220V, 50/60 Hz |
Surge current |
2A |
Power consumption |
7.5VA |
Ambient temperature |
0°C ~40°C |
Ambient humidity |
80% RH |
Vibration test |
Sweep freq. 10-55Hz, Displacement acceleration
0.5mm - 0.5G max. |
Withstand voltage |
1500V @ 1 minute |
Grounding way |
The third class grounding |
Environment requirement |
Not allowed corrosive gases, dust and rain |
Weight |
~ 0.8Kg |
Display |
LED |
Setting method |
Keypad |
|
 |
 |
Mechanic data |
 |
Mounting |
Surface-Mounted |
Dimension |
Refer to “Dimension Diagram” |
|
 |
 |
Electric data |
 |
Load Cell Specification |
LMS series high-precision tension detector
PDSA series wide-angle tension detector |
External signal input |
Line speed, DC 0-10V, input impedance 20 KΩ
Tension detector, DC 0-300mV, input impedance 20 KΩ |
Contact input |
RUN (START), input impedance 6.6 KΩ |
Contact output |
Low-tension, High-tension or Abnormal Alarm;
2 sets of output AC220V 1.0A |
Control output |
Speed signal, DC 0~10V 5mA
Tension-value signal, DC 0~10V 5mA |
Communication |
RS485 MODBUS RTU |
|
|
 |
|
 |
 |
 |
Tension controller TC-2010 |
 |
 |
 |
 |
 |
Tension controller TC-2010 |
 |
 |
 |
 |
 |
Tension controller TC-2010 |
 |
Central guiding tension control |
|
|
 |
  |
|
 |
|
 |
The application example of the picture is shoed that Tension Controller TC-2010 is applied to the tension control of central guiding in the fabric laminating machine, it could keep fabric surface be flat in laminating. |
|
|
|
 |
 |
 |
|
 |
 |